
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-468DC-POWER (Single Carrier Cabinet Environment)
9
Hardware Error Log Entries and Test to Clear
Values
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the following table when
inspecting errors in the system. By clearing error codes associated with the
Single Carrier Cabinet Power Query Test
, for example, you may also clear errors
generated from other tests in the testing sequence. Test description(s) and
recommended maintenance procedures follow for all errors that can occur
during system technician-demanded testing.
Notes:
a. Refer to EMG-XFER (Emergency Transfer) Maintenance documentation for
a description of this test.
b. Refer to EXT-DEV (External Alarm Lead) Maintenance documentation for a
description of this test.
c. Refer to RING-GEN (Analog Ring Generator) Maintenance documentation
for a description of this test.
Single Carrier Cabinet Power Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
1
1. UU is the universal cabinet number indicated in the PORT field of the Alarm Log.
0
2
2. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test environment UU
513 0 or 1 Single Carrier Cabinet
Power Query (#79)
MAJOR ON test environment UU r 2
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive; ND = Nondestructive
Single Carrier Cabinet Power Query Test (#79) X X ND
Emergency Transfer Query Test (#124) (a) X X ND
External Alarm Lead Query Test (#120) (b) X X ND
Analog Ring Generator Initialization Test (#117) (c) X X ND
Analog Ring Generator Query Test (#118) (c) X X ND