Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1140PDATA-BD (Packet Data Line Circuit Pack)
9
Error Log Entries and Test to Clear Values
Notes:
a. Error type 1 indicates the circuit pack has stopped functioning or has
been physically removed from the system. This error type does not apply
to ANN-BD, DETR-BD, S-SYN-BD, M/T-BD, or CLSFY-BD. The alarm is
logged approximately 11 minutes after removal of the circuit pack or
failure of the SAKI Sanity Test (#53).
Check for the physical presence of the circuit pack in the slot indicated by
the alarm. If the circuit pack is not present, insert one of the proper type. If
the circuit pack is present and its red LED is lit, see
LED Alarm Without
Alarm Log Entry
in Chapter 7, ‘‘LED Interpretation’’.
Table 9-453. PDATA Board Error Log Entries
Error Type
Aux
Data Associated Test
Alarm
Level
1
1. Major or Minor alarms may have been downgraded to Warning alarms based on the values used in the
set options command.
On/Off
Board Test to Clear Value
0
2
2. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
Any Any Any test port UUCSSpp sh r 1
1(a) None MINOR ON
18(b) Busyout Board WARNING OFF release board UUCSS
257(c) CC Loop Test
(#52)
MINOR ON test board UUCSS r3
513(d)
769(e)
1025(f) 4363 NPE Audit Test
(#50)
1293(g) 46088 to
46089
MINOR ON
1538(h) 46082 MINOR ON
1793(i) 46080 MINOR ON
2306(j) 46081
3330(k) 46083 MINOR ON
3840(l) 4096 to
4101
3843(m) 46097
3999(n) Any None