DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1801TONE-PT (Tone Generator)
9
b. Refer to TONE-BD (Tone-Clock Circuit Pack) section for descriptions of
these tests.
c. Refer to TDM-CLK (TDM Bus Clock) section for descriptions of these tests.
d. This test only runs on the Standby Tone-Clock circuit pack in a Port
Network with more than one Tone-Clock circuit pack (High or Critical
Reliability Option). The circuit pack must be a TN780 code with firmware
revision 2 or above.
e. Test #149 does not run on the TN2182.
Tone Generator Transmission Test (#40)
The purpose of this test is to verify that the tone generation hardware on the
tone-clock circuit pack is capable of generating a subset of system tones and a
set of test tones. This test does not verify all system tones the tone generator
produces during normal system operation.
The test is performed in two parts. For the first part, the Tone Generator is told to
generate the touch-tone digits. The digits are received and checked by a Tone
Detector touch-tone detector. If any of the digits fail, the test is repeated using a
touch-tone detector in another Tone Detector circuit pack.
For the second part, the Tone Generator is told to generate call progress tones
that are detected and identified by a tone detector. These tones are:
■ 440 Hz
■ 2225 Hz
■ Digital Count
The tone generator is then told to generate a sequence of test tones whose
output levels are measured by a tone detector. These tones are:
■ 404 Hz at 0 dB
■ 1004 Hz at -16 dB
■ 1004 Hz at 0 dB
■ 2804 Hz at 0 dB
A Tone Detector general purpose tone detector listens for the tones and
measures the quality of the tone. If any of the measured values are not within
limits, the test is repeated using a general purpose tone detector in a different
Tone Detector circuit pack. If the values are still out of the limits, the test will fail.
For all the failure cases of Test #40, do the following:
1. Check that all Tone Detector circuit packs have the same companding
mode as that administered for the system. Correct the situation if there is a
mismatch.
2. Run the long test sequence: test tone-clock PC long repeat 1.