DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-208set options
8
The following is a description of the values:
All fields on page 2 may have the same values. Pressing HELP in any field on
page 2 gives the following field help message:
Enter alarm group number: 1 to 4
The alarm group number is a way of distinguishing four different groups of
alarms. These alarm groups allow the user to specify that alarms in different
groups are handled differently from those in other groups.
Field Error Messages
All of the fields on the first page allow the same values. Only one error message
is printed for all first page fields. If the value is not one of the listed characters
(m,n,r,w,or y) then the following message is displayed:
“X” is an invalid entry; please press HELP key
All of the fields on page 2 allow the same values. If the value in one of these fields
is not numeric, the following message is displayed:
Entry must be all digits
All of the fields on pages page 2 allow the same values. If the value in one of
these fields is a digit other than 1, 2, 3, or 4, the following message is displayed:
Entry out of range
Output
After the user has entered in the changes to the options and pressed SUBMIT,
the following message appears at the bottom of the screen:
Command successfully completed
Feature Interactions
None.
m(inor)
Downgrade the major alarm to a minor alarm and report the alarm to
INADS.
n(o)
Do not log the alarm or report it to INADS.
r(eport)
Downgrade the alarm to a warning and report the warning to INADS.
w(arning)
Downgrade the alarm to a warning, log it but do not report the alarm to
INADS.
y(es)
Log and report the alarm to INADS.