xStack
®
DES-3200 Series Layer 2 Managed Fast Ethernet Switch CLI Reference Guide
458
50-2 show environment
Description
This command is used to display current status of power(s) and fan(s) on the system.
Format
show environment
Parameters
None.
Restrictions
None.
Example
To display the device environment:
DES-3200-28/ME:admin#show environment
Command: show environment
Temperature Trap State : Enabled
Temperature Log State : Enabled
Internal Power : Active
External Power : None
Current Temperature(Celsius) : 32
High Warning Temperature Threshold(Celsius) : 79
Low Warning Temperature Threshold(Celsius) : 11
DES-3200-28/ME:admin#
50-3 config temperature threshold
Description
This command is used to configure the warning threshold for high and low temperature.
Format
config temperature threshold {high <temperature -500-500> | low <temperature -500-500>}
Parameters
threshold - Specify the high and low threshold value.
high - (Optional) To configure high threshold value. The high threshold must bigger than the
low threshold.