D-Link DES-3200 Series Washer/Dryer User Manual


 
xStack
®
DES-3200 Series Layer 2 Managed Fast Ethernet Switch CLI Reference Guide
304
30-39 config mld_snooping data_driven_learning
max_learned_entry
Description
This command is used to configure the maximum number of groups that can be learned by data
driven.
When the table is full, the system will stop the learning of the new data-driven groups. Traffic for
the new groups will be dropped.
Format
config mld_snooping data_driven_learning max_learned_entry <value 1-1024>
Parameters
max_learned_entry - Specify the maximum number of groups that can be learned by data
driven. The default setting is 128.
<value 1-1024> - Enter the maximum learned entry value here. This value must be between 1
and 1024.
Restrictions
Only Administrator, Operator and Power-User level users can issue this command.
Example
To set the maximum number of groups that can be learned by data driven:
DES-3200-28/ME:admin#config mld_snooping data_driven_learning max_learned_entry
50
Command: config mld_snooping data_driven_learning max_learned_entry 50
Success.
DES-3200-28/ME:admin#
30-40 clear mld_snooping data_driven_group
Description
This command is used to delete the MLD snooping groups learned by data driven.
Format
clear mld_snooping data_driven_group [all | [vlan_name <vlan_name> | vlanid <vlanid_list>]
[<ipv6addr>| all]]
Parameters
all - Specify all VLANs to which MLD snooping groups will be deleted.
vlan_name - Specify the VLAN name.