![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/d/4c/d4ca533e-4438-49d3-b243-4b7bf83b4c42/d4ca533e-4438-49d3-b243-4b7bf83b4c42-bgf6.png)
230 iSeries and AS/400e System Builder
#0574 #0574 - #5074 Equivalent
The #0574 PCI Expansion Unit in Rack is the equivalent of a #5074 PCI Expansion Unit, but the #0574 is installed in an
#5079 1.8 M I/O Tower.
For each #5079 ordered, a default quantity of two #0574 specify codes appear on the order. One #0574 can be removed
from the #5079 order. #0574s can be RPQ added/removed to/from system inventory records, but a minimum of one #0574
must exist for each #5079 on the inventory records. If an existing #5079 is to be shared between two systems, one #0574
must be RPQ removed from that system the #5079 was ordered against and one #0574 must be RPQ added to the other
sharing system.
The #0574 indicates a #5074 installed in a #5079 rack. A #5079 is required.
The #5160 Power Distribution Unit, #5161 Power Distribution Unit, and #5163 Power Distribution Unit were withdrawn from
marketing on 12 April 2005. The #7188 Power Distribution Unit is the recommended replacement.
#0578 #0578 PCI Expansion Unit in Rack
The #0578 PCI Expansion Unit in Rack is the equivalent of a #5078 PCI Expansion Unit, but the #0578 is mounted in an
#0550/#0551/#0553/#0554/#0555 iSeries Rack. An #0578 is eight EIA units high. Conversions between an #0578 and a
#5078 are not allowed.
Up to five #0578s are mounted in a #0551/#0553/#0554/#0555 iSeries Rack depending on the amount of existing empty
space in the #0551/#0553/#0554/#0555. One #0578 can be mounted in an #0550. The #0578 can be ordered on initial,
upgrade, and MES orders. The #0578 comes with two PDU-compatible power cords.
A minimum of one PDU is required if one, two, or three #0578s are ordered to be installed in the same
#0551/#0553/#0554/#0555. A minimum of two PDUs are required if four #0578s are ordered for the same #0551. One PDU
is required for an #0578 in an #0550. Each PDU has six power sockets for connecting rack mounted devices with #1422
PDU Line Cords. Each #0578 comes with two integrated PDU compatible line cords. The #1422 PDU Line Cords are
not
usable with this expansion unit.
See #0551/#0553/#0554/#0555 for a description of available PDUs.
See “#5078 PCI Expansion Unit” on page 235 for a description of #0578 and #5078 common features.
Supported on Models 820, 830, 840
The #0578 was withdrawn from marketing on 01 October 2004. The recommended replacement is #0588.
#0588 #0588 PCI-X Expansion Unit in Rack
The #0588 PCI-X Expansion Unit in Rack is the equivalent of a #5088 PCI-X Expansion Unit, but the #0588 is mounted in
an #0550/#0551/#0553/#0554/#0555 iSeries Rack. An #0588 is 8 EIA units high. Conversions between an #0588 and a
#5088 are not allowed.
The #0588 PCI-X Expansion Unit in Rack has two redundant 575W power supplies and two integrated PDU compatible
line cords. The line cords can be connected to the same PDU or separate PDUs in the #0550/#0551/#0553/#0554/#0555
iSeries Rack. If the line cords are connected to separate PDUs, and these PDUs are connected to two different power
sources, then the #0588 has dual-line cord capability. A minimum of one PDU is required if one, two or three #0588s are
ordered to be installed in the same #0551/#0553/#0554/#0555. A minimum of two PDUs are required if four #0588s are
ordered for the same #0551/#0553/#0554/#0555. One PDU is required for an #0588 in an #0550. The #1422 PDU Line
Cords are not usable with the #0588. See #0551/#0553/#0554/#0555, for a description of available PDUs.
Up to five #0588s can be mounted in a #0551/#0553/#0554/#0555 iSeries Rack (depending on the amount of existing
empty space in the #0551/#0553/#0554/#0555), and one #0588 can be mounted in a #0550 iSeries Rack. The #0588 can
be ordered on initial, model upgrade, or MES orders.
A #9943/#9844 Base PCI IOP can be used in a #0588 PCI-X Expansion Unit in Rack, but cannot be ordered with or for the
#0588. See “#5088 PCI-X Expansion Unit” on page 237 for a description of #0588 PCI-X Expansion Unit in Rack and #5088
PCI-X Expansion Unit common features.
The #0588 is also supported in Linux partitions with SUSE Linux Enterprise Server 9 for POWER or Red Hat Enterprise
Linux AS for POWER Version 3.
Supported on Models 820, 830, 840
Minimum operating system level: OS/400 V5R2
The #0588 was withdrawn from marketing on 01 June 2006.