A SERVICE OF

logo

94 iSeries and AS/400e System Builder
#5075
(cont.)
#5075 PCI Expansion Tower
Select one of the following SPCN cables per tower:
#1463 - 2m SPCN Cable
#1464 - 6m SPCN Cable
#1465 - 15m SPCN Cable
#1466 - 30m SPCN Cable
One #14xx power cord must be specified (geography dependent).
Maximum: One #5075 PCI Expansion Tower or one #5095 PCI-X Expansion Tower
The #5075 is a Customer Install Feature.
The #5075 was withdrawn from marketing on 21 November 2003.
#5095 #5095 PCI-X Expansion Tower
The #5095 is a PCI Expansion Tower which provides I/O capability for iSeries systems. The #5095 has 7 PCI-X IOP/IOA
slots. The #5095 also supports up to 12 disk units.
A #9844 Base PCI IOP is included as “base” and should be on an initial order #5095.
The #5095 includes a bus adapter to provide the HSL-2 interface to the system. The IBM marketing configurator adds the
following to the order:
#9887 Base HSL-2 Bus Adapter (specify when attaching to copper HSL or HSL-2 loops)
For the Model 270, if this unit is attaching to HSL port A1 of the system unit HSL, the HSL cable connection to port A1
cannot exceed 6 m:
#1474 - 6m HSL to HSL-2 Cable
#1475 - 10m HSL to HSL-2 Cable
#1482 - 3.5m HSL-2 Cable
#1483 - 10m HSL-2 Cable
#1485 - 15m HSL-2 Cable
Select one of the following line cords (select two if #5138 is selected):
#1410 - 200V 6-ft Line Cord
#1411 - 200V 14-ft Line Cord
#1412 - 125V 6-ft Line Cord (US default)
#1414 - 200V 6-ft Locking Line Cord
#1415 - 200V 6-ft Watertight Line Cord
#1438 - 4.3 m 200V/10A Power Cord AU/NZ
#1439 - 4.3 m 200V/10A Power Cord EU/Asia
#1440 - 4.3 m 200V/10A Power Cord Denmark
#1441 - 4.3 m 200V/10A Power Cord S Africa
#1442 - 4.3 m 200V/10A Power Cord Swiss
#1443 - 4.3 m 200V/10A Power Cord UK
#1444 - 4.3 m 200V/10A Power Cord Italy
Select one of the following SPCN cables:
#0369 - 100 m Optical SPCN Cable
#1463 - 2 m SPCN Cable
#1464 - 6 m SPCN Cable
#1465 - 15 m SPCN Cable
#1466 - 30 m SPCN Cable
#1468 - 250 m Optical SPCN Cable
The #5095 supports seven PCI-X IOA/IOP card slots. One Integrated xSeries Server is supported in slots C1 and C2. The
#5095 has redundant power when feature #5138 is ordered or present. The #5138 includes a second 435W power supply.
A second line cord is required with the #5138 to provide redundant power support in this tower with dual-line cord capability.
If an Integrated xSeries Server is ordered as part of an MES, the #9844 Base PCI IOP (in slot C1) and any associated
IOAs must be repositioned within the system.
Maximum: One #5075 PCI Expansion Tower or one #5095 PCI-X Expansion Tower
Minimum operating system level: OS/400 V5R2
#5156 Redundant Power and Cooling
The #5156 adds an additional 575-watt power supply for redundancy and an additional cooling fan to the #5075 PCI
Expansion Tower, which attaches to Models 270.
The #5156 is a Customer Install Feature.
The #5156 was withdrawn from marketing on 01 June 2006.