25. Power Fail Reset “+025”
This option allows the owner to set the amount of time
NetMaster will store active cycle information in the
event of a power failure. The default setting for Power
Fail Reset is OFF. If Power Fail Reset is turned OFF,
the cycle will be saved for up to six years.
How to Program Power Fail Reset
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the DELICATES (+) or the COLD (-)
keypad until “PrOg” appears in the VFD. Press
the START (enter) keypad and “+001” will
appear in the VFD.
Figure 105
3. Press the DELICATES (+) or the COLD (-)
keypad to scroll through the programmable
options until “+025” appears in the VFD. Refer
to Figure 106.
Figure 106
4. When “+025” appears in the VFD, press the
START (enter) keypad. A number will appear in
the VFD. This number corresponds to the current
Power Fail Reset setting.
5. Press the DELICATES (+) or the COLD (-)
keypad to increase or decrease the current
number to the desired number selected from
Table 4. Refer to Figure 107.
Figure 107
6. Press the START (enter) keypad when the
correct number appears in the VFD. The next
option, “+026”, will appear in the VFD.
NOTE: To program “+026” (Set Real-Time Clock
Minutes), refer to option 26. To program other
options, refer to the appropriate section.
How to Exit Programming Feature
1. Be sure the control shows a programmable option,
not a value.
2. While pressing and holding the NORMAL
keypad with one hand, press the PERM PRESS
keypad with the other hand. The control will
revert back to the ready mode. Refer to Figure 2.