Alliance Laundry Systems 1336 Washer User Manual


 
Allen-Bradley 1305-Series AC Drives
F232120
74
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Human Interface Module (HIM) Operation
When power is first applied to the drive, the HIM will
cycle through a series of displays. The displays will
show drive name, HIM ID number, and
communications status. Upon completion, the Status
Display will be displayed. If a fault condition exists, it
will appear on the display.
NOTE: If “Not Enabled” is displayed, the Enable
input is not active. Check that the door is closed
and locked, or that all necessary jumpers are in
place. Refer to Section 2 of this manual.
Figure 45
HIM – Key Explanation
Escape key. Use to return to last or original
position.
Select key. Use to move cursor position.
Up arrow key. Scroll up.
Down arrow key. Scroll down.
Enter key. Use to enter program selection or new
parameter value.
The structure charts on the following pages illustrate
how to navigate between the levels to obtain
information necessary for troubleshooting for earlier
and later HIM versions.
The HIM Structure is broken into 4 levels: Operator
Level, Mode Level, Group Level (Main File for earlier
versions), and Parameter Level.
In the Group Level (Main File for earlier versions),
only three Groups are used: Metering, Faults, and
Linear List. Most diagnostic information is found in
Metering or Faults.
ESC SEL
Stopped
+0.00 Hz
U093M
Human Interface Module (HIM)
ESC
SEL