160 Series Drive Control Logic Chart
The following truth table (Tables 26 - 30) designates
the preset speed selection based on the inputs to the
control terminals. A disconnected control terminal will
seek the high signal voltage condition (greater than
10V DC).
To activate a control input (i.e., SW1, SW2, etc.), the
terminal is connected to a common terminal (TB3-3 or
TB3-7) to lower the signal voltage to a low condition
(less than 1 Volt DC).
Pocket Hardmount
V Control and A control
H – Control Voltage High (greater than 10V DC)
L – Control Voltage Low (less than 1V DC)
0 = No signal received
1 = Signal received
SW3 SW2 SW1 STF Stop STR
Preset Status –
Parameter 15
Input Status –
Parameter 12
DC Volt Meter Red Probe Terminal Location
421685
DC Volt Meter Black Probe Terminal Location
333333
Action
Frequency
Preset
Parameter #
Terminal
#4
(SW3)
Terminal
#2
(SW2)
Terminal
#1
(SW1)
Terminal
#6
(STF)
Terminal
#8
(Stop)
Terminal
#5
(STR)
Not Used
SW3
SW2
SW1
Not Used
STF
Stop
STR
Idle
N/A H H H H L/H H 0000000/10
1/2 Wash Speed Forward
62 H H L L L H 00010110
1/2 Wash Speed Reverse
62 H H L H L L 00010011
Wash Speed Forward
63 H L H L L H 00100110
Wash Speed Reverse
63 H L H H L L 00100011
Distribution Speed
65 L H H L L H 01000110
Spin 1
64 H L L L L H 00110110
Spin 2
67 L L H L L H 01100110
Spin 3
66 L H L L L H 01010110
Pocket Hardmount
WE-6 Control - Design 5 and Earlier
H – Control Voltage High (greater than 10V DC)
L – Control Voltage Low (less than 1V DC)
0 = No signal received
1 = Signal received
SW3 SW2 SW1 STF Stop STR
Preset Status –
Parameter 15
Input Status –
Parameter 12
DC Volt Meter Red Probe Terminal Location
421685
DC Volt Meter Black Probe Terminal Location
333333
Action
Frequency
Preset
Parameter #
Terminal
#4
(SW3)
Terminal
#2
(SW2)
Terminal
#1
(SW1)
Terminal
#6
(STF)
Terminal
#8
(Stop)
Terminal
#5
(STR)
Not Used
SW3
SW2
SW1
Not Used
STF
Stop
STR
Idle
N/A H H H H L/H H 0000000/10
1/2 Wash Speed Forward
65 L H H L L H 01000110
1/2 Wash Speed Reverse
65 L H H H L L 01000011
Wash Speed Forward
63 H L H L L H 00100110
Wash Speed Reverse
63 H L H H L L 00100011
Distribution Speed
62 H H L L L H 00010110
Medium Extract/Spray Rinse
67 L L H L L H 01100110
High 1 Extract
66 L H L L L H 01010110
High 2 Extract
64 H L L L L H 00110110
High 3 Extract
68 L L L L L H 01110110
Table 26