Alliance Laundry Systems 1336 Washer User Manual


 
PowerFlex 40 and 400 Drive Control Logic
25
F232120
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Table 16 (continued)
PowerFlex 40
Parameter
Group and
Number
PowerFlex 400 Parameter Group
and Number
Parameter
Description
Function
d016 d320 Control
Firmware
Ve rsion
Displays the AC drive's firmware
version. For PowerFlex 40 drives, this
will be 70.xx, 80.xx or 90.xx. For
PowerFlex 400 drives, this will be 14.01.
d017 d321 Drive Type Displays the numeric code of the drive's
rating (e.g., 4508 = 5hp 200V drive)
d018 b012 Elapsed Run
Time
Displays the accumulated time the drive
has output power. The display is in 10-
hour increments (e.g., a display of 1
represents a value of 10 hours).
d019 d319 Testpoint Data Displays a hexadecimal value of the
“Testpoint Selection” in parameter
A102.
d020 d305 Analog In
(0-10V)
Displays the value (in percentage) of the
voltage at terminal 13(e.g.,
100.0%=10V)
d021 d306 Analog In
(4-20mA)
Displays the value (in percentage) of the
current at terminal 15 (e.g., 0.0%=4mA;
100.0%=20mA)
d022 b010 Output Power Displays the kilowatts present at
terminals U, V and W (in kW).
d023 d318 Output Power
Factor
Displays the angle in electrical degrees
between the motor voltage and the motor
current.
d024 b014 Drive
Temperature
Displays the present operating
temperature (in Celsius) of the drive's
internal power devices. Refer to Fault
008 in Table 20.
d025 N/A Counter Status Not applicable to Alliance Laundry
Systems' equipment. Refer to the manual
supplied with the PowerFlex drive for
detailed information.
d026 N/A Timer Status Not applicable to Alliance Laundry
Systems' equipment. Refer to the manual
supplied with the PowerFlex drive for
detailed information.
d028 N/A Step Logic
Status
Not applicable to Alliance Laundry
Systems' equipment. Refer to the manual
supplied with the PowerFlex drive for
detailed information.
Table 16 (continued)