Alliance Laundry Systems 1336 Washer User Manual


 
PowerFlex 40 and 400 Drive Control Logic
F232120
18
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
PowerFlex 40 Drive Control Logic Chart
PowerFlex 400 Drive Control Logic Chart
Cabinet Freestanding
WE-6 control
H – Signal Voltage High (approximately 24V DC)
L – Signal Voltage Low (less than 1V DC)
0 = No signal received
1 = Signal received
Digital
In 3
Digital
In 2
Digital
In 1
Stop Rev Fwd
Digital Input
Status – Parameter
d014
Control Input
Status – Parameter
d013
DC Volt Meter Red Probe Terminal Location
07 06 05 01 03 02
DC Volt Meter Black Probe Terminal Location
04 04 04 04 04 04
Action
Frequency
Preset
Parameter #
Terminal
#07
(SW3)
Terminal
#06
(SW2)
Terminal
#05
(SW1)
Terminal
#01
(Stop)
Terminal
#03
(STR)
Terminal
#02
(STF)
*Digital In 4
Digital In 3
(SW3)
Digital In 2
(SW2)
Digital In 1
(SW1)
DB Trans
On
Stop
Rev (STR)
Fwd (STF)
Idle
N/A H H H L/H H H 0 0 0 0 0 0/1 0 0
1/2 Wash Speed Forward
74 LHHL HL*11000101
1/2 Wash Speed Reverse
74 L H H L L H 01000110
Wash Speed Forward
72 HLHL HL*10100101
Wash Speed Reverse
72 H L H L L H 00100110
Distribution Speed
71 H H L L H L *10010101
Medium Extract
76 LLHLHL*11100101
High 1 Extract
75 L H L L H L *11010101
High 2 Extract
73 H L L L H L *10110101
High 3 Extract
77 L L L L H L *11110101
*If digital in 4 is wired to the Forward Input terminal #02, this input will be a “1” whenever the drive receives a forward command. Disregard otherwise.
Table 12
Cabinet Freestanding (250 Model Only)
WE-6 control
H – Signal Voltage High (greater than 10V DC)
L – Signal Voltage Low (less than 1V DC)
0 = No signal received
1 = Signal received
Digital
In 3
Digital
In 2
Digital
In 1
Fwd Stop Rev
Control Input Status – Parameter d302
DC Volt Meter Red Probe Terminal Location
07 06 05 02 01 03
DC Volt Meter Black Probe Terminal Location
04 04 04 04 04 04
Action
Frequency
Preset
Parameter #
Terminal
#07
(SW3)
Terminal
#06
(SW2)
Terminal
#05
(SW1)
Terminal
#02
(STF)
Terminal
#01
(Stop)
Terminal
#03
(STR)
Not Used
*Digital In 4
Digital In 3
(SW3)
Digital In 2
(SW2)
Digital In 1
(SW1)
Stop
Rev (STR)
Fwd (STF)
Idle
N/A H H H H L or H H 000000/100
1/2 Wash Speed Forward
355 L H H L L H 0 *1 1 0 0 1 0 1
1/2 Wash Speed Reverse
355 L H H H L L 00100110
Wash Speed Forward
145 H L H L L H 0 *1 0 1 0 1 0 1
Wash Speed Reverse
145 H L H H L L 00010110
Distribution Speed
144 H H L L L H 0 *1 0 0 1 1 0 1
Medium Extract
357 L L H L L H 0 *1 1 1 0 1 0 1
High 1 Extract
356 L H L L L H 0 *1 1 0 1 1 0 1
High 2 Extract
146 H L L L L H 0 *1 0 1 1 1 0 1
High 3 Extract
358 L L L L L H 0 *1 1 1 1 1 0 1
*If digital in 4 is wired to the Forward Input terminal #02, this input will be a “1” whenever the drive receives a forward command. Disregard otherwise.
Table 13