Alliance Laundry Systems 1336 Washer User Manual


 
Allen-Bradley 1305-Series AC Drives
73
F232120
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
AC Drive Diagnostics/Parameter
Viewing
Human Interface Module (HIM or
Parameter Unit)
Installation/Removal
The following are instructions for installing/removing
the Human Interface Module (P/N F370597) on the
drive for parameter viewing and basic troubleshooting.
The parameter unit (F370597) and instructions
(F232120) are included in the Parameter Kit (P/N
F744501).
Installing the HIM
1. Remove power from machine at main
disconnect. Delay approximately three minutes.
2. Lower the hinged panel located below the HIM.
3. Slide blank panel cover toward base of drive and
remove it. Place top edge of HIM approximately
1/2 inch from top edge of the cover. Push inward
on bottom of HIM and slide HIM up (toward the
top of the drive) into position.
Removing the HIM
1. Remove power from machine at main
disconnect. Delay approximately three minutes.
2. Lower hinged panel located below HIM.
3. Press retaining lever located directly beneath
HIM. Slide HIM downward and remove it from
drive.
4. Reinstall blank panel cover. Close hinged panel.
External HIM Connection
The HIM unit can be installed using an adapter cable
(P/N P370716). This method of attaching the HIM
uses an external connector shown in Figure 44. The
HIM unit operates in the same manner in this
configuration.
NOTE: If the HIM is removed while the drive is
powered, a communication fault (Serial Fault #10)
will occur and the drive will be disabled. Cycle
power to the drive to reset the fault condition.
Figure 44
CAUTION
Users are prohibited from changing
parameter values unless specifically
instructed by the washer-extractor
manufacturer. Modification to parameter
values may present potential harmful
operating conditions for both hardware and
personnel.
W673
WARNING
To reduce risk of electric shock, severe
injury or death, allow machine power to
remain off for three minutes minimum prior
to working in and around AC drive. Proceed
with caution.
W662
Human Interface
Module
Hinged Panel
Retaining Lever
External HIM
Cable Connection
Blank Panel Cover
E
S
C
S
E
L
Stopped
+0.00 Hz
U079ME3
A