Alliance Laundry Systems 1336 Washer User Manual


 
PowerFlex 40 and 400 Drive Control Logic
F232120
14
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
PowerFlex 40 Drive Control Logic Chart
Cabinet Hardmount
“A” control, “B” control, “V” Control and EDC/Netmaster Control
H – Signal Voltage High (approximately 24V DC)
L – Signal Voltage Low (less than 1V DC)
0 = No signal received
1 = Signal received
Digital
In 3
Digital
In 2
Digital
In 1
Stop Rev Fwd
Digital Input
Status – Parameter
d014
Control Input
Status – Parameter
d013
DC Volt Meter Red Probe Terminal Location
07 06 05 01 03 02
DC Volt Meter Black Probe Terminal Location
04 04 04 04 04 04
Action
Frequency
Preset
Parameter #
Terminal
#07
(SW3)
Terminal
#06
(SW2)
Terminal
#05
(SW1)
Terminal
#01
(Stop)
Terminal
#03
(STR)
Terminal
#02
(STF)
*Digital In 4
Digital In 3
(SW3)
Digital In 2
(SW2)
Digital In 1
(SW1)
DB Trans
On
Stop
Rev (STR)
Fwd (STF)
Idle
N/A H H H L/H H H 000000/100
1/2 Wash Speed Forward
71 H H L L H L *10010101
1/2 Wash Speed Reverse
71 H H L L L H 00010110
Wash Speed Forward
72 HLHL HL*10100101
Wash Speed Reverse
72 H L H L L H 00100110
Distribution Speed
74 LHHL HL*11000101
Spin 1
73 H L L L H L *10110101
Spin 2
76 LLHL HL*11100101
Spin 3
75 L H L L H L *11010101
*If digital in 4 is wired to the Forward Input terminal #02, this input will be a “1” whenever the drive receives a forward command. Disregard otherwise.
Cabinet Hardmount
Galaxy control, Quantum control and UniMac Software Control
H – Signal Voltage High (approximately 24V DC)
L – Signal Voltage Low (less than 1V DC)
0 = No signal received
1 = Signal received
Digital
In 3
Digital
In 2
Digital
In 1
Stop Rev Fwd
Digital Input
Status – Parameter
d014
Control Input
Status – Parameter
d013
DC Volt Meter Red Probe Terminal Location
07 06 05 01 03 02
DC Volt Meter Black Probe Terminal Location
04 04 04 04 04 04
Action
Frequency
Preset
Parameter #
Terminal
#07
(SW3)
Terminal
#06
(SW2)
Terminal
#05
(SW1)
Terminal
#01
(Stop)
Terminal
#03
(STR)
Terminal
#02
(STF)
*Digital In 4
Digital In 3
Digital In 2
Digital In 1
DB Trans
On
Stop
Rev
Fwd
Idle
N/A H H H L/ H H H 000000/100
Reduced Wash speed (ccw)
70 H H H L L H 00000110
Reduced Wash Speed (cw)
70 H H H L H L 00000101
Wash Speed (ccw)
72 H L H L L H 00100110
Wash Speed (cw)
72 H L H L H L 00100101
Distribution Speed 1 (ccw)
71 H H L L L H 00010110
Extract Speed 1 (ccw)
76 L L H L L H 01100110
Extract Speed 2 (ccw)
75 L H L L L H 01010110
Extract Speed 3 (ccw)
73 H L L L L H 00110110
Extract Speed 4 (ccw)
77 L L L L L H 01110110
Extract Speed 5 (ccw)
74 L H H L L H 01000110
Table 8