Alliance Laundry Systems 1336 Washer User Manual


 
PowerFlex 40 and 400 Drive Control Logic
17
F232120
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Pocket Hardmount
WE-6 control - Design 6, 7 and 8
H – Signal Voltage High (approximately 24V DC)
L – Signal Voltage Low (less than 1V DC)
0 = No signal received
1 = Signal received
Digital
In 3
Digital
In 2
Digital
In 1
Stop Rev Fwd
Digital Input
Status – Parameter
d014
Control Input
Status – Parameter
d013
DC Volt Meter Red Probe Terminal Location
07 06 05 01 03 02
DC Volt Meter Black Probe Terminal Location
04 04 04 04 04 04
Action
Frequency
Preset
Parameter #
Terminal
#07
(SW3)
Terminal
#06
(SW2)
Terminal
#05
(SW1)
Terminal
#01
(Stop)
Terminal
#03
(STR)
Terminal
#02
(STF)
*Digital In 4
Digital In 3
(SW3)
Digital In 2
(SW2)
Digital In 1
(SW1)
DB Trans
On
Stop
Rev (STR)
Fwd (STF)
Idle
N/A H H H L/H H H 000000/100
1/2 Wash Speed Forward
70 HHHL HL*10000101
1/2 Wash Speed Reverse
70 H H H L L H 00000110
Wash Speed Forward
72 HLHL HL*10100101
Wash Speed Reverse
72 H L H L L H 00100110
Distribution Speed
71 H H L L H L *10010101
Medium Extract/Spray Rinse
76 LLHLHL*11100101
Extract Speed 1
75 L H L L H L *11010101
Extract Speed 2
73 H L L L H L *10110101
Extract Speed 3 (default)
77 L L L L H L *11110101
Extract Speed 3 (maximum)
74 LLHLHL*11000101
*If digital in 4 is wired to the Forward Input terminal #02, this input will be a “1” whenever the drive receives a forward command. Disregard otherwise.
Table 11