MX3X Reference Guide E-EQ-MX3XRG-H
Factory Default Settings
Factory Default Settings
Main
Port 1 Internal
Port 2 Disabled
Power Port 1 while asleep Disabled
Send key messages WEDGE Enabled
Keys
Left Scan
Right Enter
COM Ports (COM1- COM2 – COM3)
Baud Rate 9600
Parity None
Stop Bits 1
Data Bits 8
Notes:
If the internal scanner has to be configured to operate at any communication settings other
than 9600, N, 8, 1 and the computer either loses power or a cold boot command is entered,
the Scanner applet must be reconfigured to match the scanner communication settings.
When there is no internal scanner, Port 1 is disabled and the Left Scan button is an Enter
key.
ActiveSync will not work over a COM port if that COM port is enabled in the Scanner
applet as a scanner input. For example, if COM 1 is being used by the scanner, COM 1
can’t be used by any other program.
When an RFID module is not installed, the RFID option on the Keys tab is greyed out. See