Fisher & Paykel 517735 Washer User Manual


 
- 83 -
RECIRCULATING VALVE
PUMP
The pump is the same as Phase 5. The pump forms part of the power supply. If it not connected
Smartdrive will appear to have no power. The pump resistance is 33 ohms.
E.4 OPTION ADJUSTMENT MODE for IW
In Option Adjustment Mode the following adjustments may be made: -
The fill level selected by Auto Water Level.
The type of rinse.
The temperature of the wash.
The spin speed for Creasables.
The recovery routine selected when a load goes out of balance.
The number of beeps at the end of the cycle.
Adjust Options Menu
auto water temp
auto rinse other
With Smartdrive powered on push the OPTIONS button and hold down for 4 seconds. The Adjust
Options Menu will be displayed. Push the small button next to the option to be adjusted. The display will
change to the choices available for that option. To set the option push the small button next to it. The
display screen will highlight the selection before returning to the main screen.