Fisher & Paykel 517735 Washer User Manual


 
- 60 -
160. (10100000) Phase 1 to 5 - Bowl Engaged During Agitate
The bowl has re-engaged itself during agitate. Possible causes for this are a leak in the air bell,
bowl is over-loaded with clothes, the clutch has jammed or is fouled with a foreign object.
Primary Source - Mechanical
Action
1. Make sure the bowl is not overloaded with too many clothes.
2. Check that the rotating bowl assembly is not jammed to the agitator with any foreign object
that may be caught under the agitator skirt.
3. Check that the clutch teeth are not locked together with dirt, lint, etc.
4. If none of the above appear to be at fault, then check the air bell at the bottom of the inner
bowl for leaks.
Secondary Source - Motor Controller (Phase 1 to 4 Only).
Action - If Smartdrive is empty of water when faulting it is possible that the pump circuit is
faulty and has caused a pump out during wash. This would cause the bowl to re-engage during
agitate and the Motor Controller to display this fault. Replace Motor Controller.
161. (10100001) Phase 2 to 5 – Motor Controller Fault
The Motor Controller checks the voltage configuration (i.e. 110v or 230V) against its EEPROM
on power up. Should there be a mismatch, this error is flagged.
Primary Source - Motor Controller
Action - Replace Motor Controller.
162. (10100010) Phase 3 to 5 Brake Deceleration Time-out Fault
During the brake mode the Motor Controller has detected that the bowl has not come to a stop
in the permitted time once dropping below 100 RPM. This fault has been installed for software
testing only.
163. (10100011) Phase 4 to 5 - Motor Controller Fault
The Motor Controller has internally sensed a connection is open circuit. The cold valve cannot
be operated with this condition.
Primary Source - Motor Controller.
Action - Replace Motor Controller.