Fisher & Paykel 517735 Washer User Manual


 
- 77 -
WM80 CONDENSATION KIT – May 1996 – Phase 2 & 3 only
A condensation kit is available to reduce build up in the console area and around the electronics is
available as part number 472976.
This kit must be fitted to all Phase 2 & 3 Smartdrive where the display module has failed due to
condensation or there is condensation present in the console area.
Common symptoms caused by condensation in the display module are:-
1. Start/Pause button hard to push or not working.
2. Smartdrive enters Option Adjustment Mode as soon as Power button is pressed.
3. Smartdrive enters Demonstration Mode as soon as Power button is pressed.
4. No response from the Power button.
5. The customer can only operate Smartdrive by using Delay Start.
WM81 PUMP SHIELD 5KG SMARTDRIVE – September 1996 -
Phases 1 to 4
Under some conditions, especially with over sudsing or splash over, water
can run down the side of the 5kg Smartdrive outer bowl and drip directly
onto the pump bracket causing the pump to corrode or burn out.
A shield has been designed that can clip into place above the pump bracket
to protect the pump from water damage.
When servicing any 5kg Smartdrive, without a shield, for pump related problems a shield should be fitted.
The shield is available under p.n. 426292.
To fit the shield remove the inspection hatch, make sure the legs of the drain hose clamp are facing
towards the centre of Smartdrive, apply a small amount of silicone sealant to the shield where it clips onto
the outer bowl, hook the shield onto the back pillar above the pump bracket then clip the shield into place
by pushing the front clip section onto the front pillar above the pump bracket.