Fisher & Paykel 517735 Washer User Manual


 
- 30 -
7.4 Adjusting the Volume of Water Used in the Water Saver
Option (GW only) – Phase 3 to 5
You can increase or decrease the volume of water added during the shower rinse on the Water Saver
option. Enter the Option Adjustment Mode. Use the WATER LEVEL buttons to select the volume of
water you wish to be used in the shower rinse
HIGH WATER LED ON more water
MED WATER LED ON Default set water volume
LOW WATER LED ON less water
Press POWER to return to normal mode.
7.5 Auto Water Fill Level Adjustment (GW only) Phase 3-5
If the user is not satisfied with the level that Smartdrive fills to on auto water level, they can increase or
decrease the fill level that auto will select.
NB. If there is not enough water for the load, we recommend you check by pausing Smartdrive and
pushing the clothes down to see how much spare water is at the bottom of the bowl. Clothes often float
and Smartdrive can sense the water under the clothes.
Enter the Option Adjustment Mode. Use the cycle buttons to increase or decrease the amount of water
selected.
FAVOURITE LED on less water
PERM. PRESS LED on default set level
WOOL LED on more water
+
DELICATE LED on more water
++
REGULAR LED on more water
+++
7.6 Out Of Balance Recovery Adjustment (GW and MW only)
Phase 3-5
When Smartdrive is spinning it senses if the wash load is out of balance. It stops and retries to spin. If
Smartdrive still senses an unbalanced load it will stop, give a short burst of beeps every five seconds and
the RINSE or SPIN light will flash. The load must be redistributed more evenly. However, GW and MW
models have an option where Smartdrive will try to automatically correct the out of balance load. If it
detects an unbalanced load, it will fill with water and agitate to redistribute the load before trying to spin
up again.
Smartdrive has this option turned off to conserve water. To programme Smartdrive to automatically try
and correct out of balance loads follow the instructions below.
1. Enter the Option Adjustment Mode as explained in section 7.0.
2. Use the HEAVY DUTY button to select the Out of Balance recovery option you prefer.
HEAVY DUTY light on = automatic
HEAVY DUTY light off = stops
3. Press POWER to return to normal mode.