55
TROUBLESHOOTING TESTS
120VAC Electrical Supply
1. Check for 120VAC on the power cord connection to the line filter. If no AC power is present,
replace the power cord.
2. Check for 120VAC on the line filter connection to the machine controller. If no AC power is
present, replace line filter.
3. Check for 120VAC to the control board. With the washer off but connected to the AC outlet,
measure the AC voltage between Pins 4 and 2 at connector P16.
• If 120VAC is present, continue with remaining Trouble Shooting Tests as needed.
• If voltage is not present, check circuit breaker or fuse box, power cord connection at outlet
and washer.
Water Inlet and Dispenser Solenoid Test
This test checks for 120VAC to the water inlet and dispenser valves, the electrical connections to the
valves and the valves themselves.
1. Check the electrical connections to the valves.
2. If any valve solenoid does not activate, measure the voltage across the pins as shown in the
following table. The voltage should be equal to the incoming line voltage.
3. If no voltage is present at any of these test points and voltage at the wall outlet is normal, the
control board has a faulty relay. Replace the control board.
4. If voltage measurements are correct, check the individual solenoid valve. Unplug the washer
and disconnect connector P13 from the control board.
5. Check the resistance at the contacts shown in the following table. If resistance is outside of
range, replace the complete water inlet and dispenser assembly.
1
2
3
4
5
6
9
9
9
9
9
9
cold water valve
hot water valve
detergent dispenser valve
fabric softener dispenser valve
bleach dispenser valve
fresh water valve
P13 - Pin #
P13 - Pin #
Function
Cold water valve
Hot water valve
Detergent dispenser valve
Fabric dispenser valve
Bleach dispenser valve
Fresh water valve
800 - 1200
800 - 1200
800 - 1200
800 - 1200
800 - 1200
800 - 1200
P13 - 1 (YL/RD)
P13 - 2 (TN/RD)
P13 - 3 (TN/OR)
P13 - 4 (OR/BK)
P13 - 5 (BU/OR)
P13 - 6 (WH/OR)
SOLENOID TESTED
CONTACTS
RESISTANCE (
ΩΩ
ΩΩ
Ω)
FOR 120VAC
P13 - 9 (WH/GN)
P13 - 9 (WH/GN)
P13 - 9 (WH/GN)
P13 - 9 (WH/GN)
P13 - 9 (WH/GN)
P13 - 9 (WH/GN)