50
NUTATE AND RECIRCULATE TEST
This test sequence assumes the control is off. The test will timeout after 3 minutes of use.
PRESS TOUCHPAD DISPLAY CONTROL ACTION
1 SOAK Key Dance key press #1
2 CYCLE SIGNAL Key Dance key press #2
3 SOAK Key Dance key press #3
4CYCLE SIGNAL Key Dance key press #4
Presses #1 - #4 must be completed in 5 seconds or the key
dance is not valid.
5WATER TEMP Key press #5, “00” on the display
6WATER TEMP Cold Water Inlet Valve and Fabric Softener dispenser valve
on. Cold/Cold and Normal (above SOIL LEVEL) LEDs will
turn on.
7 SOIL LEVEL Normal LED will turn off and Heavy LED will turn on. Fabric
softener valve will shut off and Fresh water valve will turn on.
8WATER TEMP Cold/Cold LED turns off and Hot/Cold LED turns on. Cold
inlet valve turns off and Hot inlet valve turns on.
9WATER TEMP Both hot and cold inlet valves turn on.
10 None Wait about 10 seconds until enough water is in tub.
11 WATER TEMP All valves turn off.
12 WHITEST WHITES Whitest Whites LED on Unit is now set to 150 RPM nutate speed. Motor doesn’t start
until START is pressed.
13 START Wash LED flashes, then
Rinse LED turns on
Wash plate begins nutating at 150 RPM.
14 HEAVY DUTY,
NORMAL,
JEANS/DARKS,
BULKY ITEMS
Wash LED flashes, then
Rinse LED turns on
These keys can increase the nutate speed if necessary
(optional).
15 EXTEND SPIN Extend Spin LED on Pump should turn on in recirculate mode. Press EXTEND
SPIN again to turn off pump.
16 STOP/CANCEL All LEDs Off Cancel all diagnostics, go back to Off mode. You may want
to spin and drain out the water in the unit after this test.
Pump Drain/Recirculation
4. Press the EXTRA RINSE keypad to operate the pump motor in Drain. Press the EXTEND SPIN
keypad to run the pump motor in Recirculation. Pressing these keypads a second time turns the pump
motor off.