Alliance Laundry Systems PHM1263R Washer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Error Codes
F8208801
52
Table 16 (continued)
Display Description
Cause/
Corrective Action
E dL Door Lock Error Door does not lock immeadiately upon closing (open and
reclose door) or doesn’t unlock 5 seconds after cycle
completion. Power down machine and retry.
E do Door Open Error Control detects door open. Caused by pulling on door while
locked or about to lock. Correct inoperative door locking
system. End cycle. Power down machine to clear.
E Ub Unbalance Error Unable to balance load. Redistribute load and run cycle.
door Door Open Indicator Door is not closed in Start Mode. If door is closed, check for
improper wiring or faulty door switch.
E dr Drain Alarm Error Machine not drained within 15 minutes (or other programmed
length of time) in any drain step. End cycle. Power down
machine to clear.
E Ht Heat Alarm Error Programmed heat alarm time of 120 minutes or other
programmed length of time is exceeded. Turns off heater
output for remainder of cycle.
E oP Open Temperature Sensor Error Control senses temperature less than 0°F (-18°C) in machine
equipped with temperature sensor. Heater and thermistor
related operations are disabled.
E SH Shorted Temperature Sensor Error Control senses temperature greater than 220°F (104°C) in
machine equipped with temperature sensor. Heater and
thermistor related operations are disabled for remainder of
cycle.
E ro Rotation Sensor Error Invalid signal received from Rotation Sensor. Control will
activate coast times to complete cycle.
E FS Frame Balance Switch Error Control detects Frame Balance Switch open. End cycle.
E db Drive Balance Switch Error Control detects VFD Balance Switch input closed at start of
drain step. End cycle. Power down machine to clear.
E Ld Water Leak Detection Error If control senses a drop in water level during diagnostic
testing, power down machine to clear. When error occurs
during a cycle, “E Ld” is displayed for one minute after
opening the door at the end of the cycle. When the error
occurs during the test, “E Ld” is displayed immediately after
the test until the machine is powered down to clear the error.
ESd Slow Drain Error If control shows error after door is open (when cycle is
completed) for one minute, the error information will be
logged in audit data.
Table 16