Alliance Laundry Systems PHM1263R Washer User Manual


 
Programming Control
39
F8208801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
20. Medium Water Level “FnEd”
This option allows the owner to program the medium
water level during fill and tumble of all cycles.
How to Program Medium Water Level
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the #3 ( ) or the #6 ( ) keypad until
Prog” appears in the display. Press the START
(enter) keypad and “dCYC” will appear in the
display.
3. Press the #3 ( ) or the #6 ( ) keypad to scroll
through the programmable options until “FnEd
appears in the display.
4. When “FnEd” appears in the display, press the
START (enter) keypad. A number will appear in
the display. This number corresponds to the
current medium water level during tumble and
fill of all cycles.
5. Press the #3 ( ) or the #6 ( ) keypad to increase
or decrease the current water level to the desired
water level.
NOTE: The Medium Water Level value can be set
from 11 to 20.
6. Press the START (enter) keypad when the correct
number appears in the display. The next option,
FHI”, will appear in the display.
NOTE: To program “FHI” (High Water Level),
refer to option 21. To program other options, refer
to the appropriate section.
How to Exit Programming Feature
Press the #5 (<) keypad until the control returns to
Start Mode.
21. High Water Level “FHI”
This option allows the owner to program the high
water level during fill and tumble of all cycles.
How to Program High Water Level
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the #3 ( ) or the #6 ( ) keypad until
Prog” appears in the display. Press the START
(enter) keypad and “dCYC” will appear in the
display.
3. Press the #3 ( ) or the #6 ( ) keypad to scroll
through the programmable options until “FHI
appears in the display.
4. When “FHI” appears in the display, press the
START (enter) keypad. A number will appear in
the display. This number corresponds to the
current high water level during tumble and fill of
all cycles.
5. Press the #3 ( ) or the #6 ( ) keypad to increase
or decrease the current water level to the desired
water level.
NOTE: The High Water Level value can be set
from 21 to 30.
6. Press the START (enter) keypad when the correct
number appears in the display. The next option,
tCF”, will appear in the display.
NOTE: To program “tCF” (Temperature
Controlled Fill), refer to option 22. To program
other options, refer to the appropriate section.
How to Exit Programming Feature
Press the #5 (<) keypad until the control returns to