Alliance Laundry Systems PHM1263R Washer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming Control
F8208801
40
22. Temperature Controlled Fill
Enable/Disable “tCF”
This option allows the owner to enable or disable a
Temperature Controlled Fill. When enabled, the
control will regulate the temperature of the fill to the
temperature programmed in options 8, 9 and 10.
How to Program Temperature Controlled
Fill
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the #3 ( ) or the #6 ( ) keypad until
Prog” appears in the display. Press the START
(enter) keypad and “dCYC” will appear in the
display.
3. Press the #3 ( ) or the #6 ( ) keypad to scroll
through the programmable options until “tCF
appears in the display.
4. When “tCF” appears in the display, press the
START (enter) keypad. A number will appear in
the display. This number (found below)
corresponds to the current Temperature
Controlled Fill status.
“on” = Temperature Controlled Fill Enabled
“oFF” = Temperature Controlled Fill Disabled
5. Press the #3 ( ) or the #6 ( ) keypad to change
the current status.
6. Press the START (enter) keypad when the
desired status appears in the display. The next
option, “ALd”, will appear on the display.
NOTE: To program “ALd” (Auto-Water Leak
Detection), refer to option 23. To program other
options, refer to the appropriate section.
How to Exit Programming Feature
Press the #5 (<) keypad until the control returns to
Start Mode.
>
<
>
<
>
<