Alliance Laundry Systems PHM1263R Washer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Testing Machine and Electronic Control Functions
F8208801
46
Diagnostic Test Descriptions
Front End Control Software Version
Number Test
This option displays the front end control software
version number. To start test, control must be in the
Testing Mode. Refer to How to Enter Testing Feature
at the beginning of this section.
To enter, press the START (enter) keypad. The display
will show “S xx” where “xx” is the front end control
software version number.
To exit the Front End Control Software Version
Number Test, press the #5 (<) keypad. The control will
return to the testing mode.
Output Board Control Software Version
Number
This option displays the output board control software
version number. To start test, control must be in the
Testing Mode. Refer to How to Enter Testing Feature
at the beginning of this section.
To enter, press the START (enter) keypad. The display
will show “o xx” where “xx” is the output board
control software version number.
To exit the Output Board Control Software Version
Number Test, press the #5 (<) keypad. The control will
return to the testing mode.
Output Board Water Level Sensor Trim
Value
This option displays the output board water level
sensor trim value. To start test, control must be in the
Testing Mode. Refer to How to Enter Testing Feature
at the beginning of this section.
To enter, press the START (enter) keypad. The display
will show “txxx” where “xxx” is the trim value sent
from the output board to the front end control.
To exit the Output Board Water Level Sensor Trim
Value, press the #5 (<) keypad. The control will return
to the testing mode.
Access Panel Opening Test
This option tests the access panel switch. To start test,
control must be in the Testing Mode. Refer to How to
Enter Testing Feature at the beginning of this section.
To enter, press the START (enter) keypad. The display
will show “A oP” when the access panel switch is
open and “A CL” when the access panel switch is
closed.
The access panel switch has to be closed for at least
one second and opened for at least a half a second for
the display to change. This test will add a count to the
access panel opening counter for the audit and save the
date/time for every opening of the test.
To exit the Access Panel Opening Test, press the #5
(<) keypad. The control will return to the testing
mode.
Door Switch Input Test
This test will display whether the washer door is open
or closed.
To start test, control must be in the Testing Mode.
Refer to How to Enter Testing Feature at the beginning
of this section.
To enter, press the START (enter) keypad. If the door
is closed, the display will show “drCL. If the door is
open, the display will show “drOP”.
To exit the test, press the #5 (<) keypad. The control
will return to the testing mode.
Door Lock Input Test
This test will display whether the door is locked or
unlocked.
To start test, control must be in the Testing Mode.
Refer to How to Enter Testing Feature at the beginning
of this section.
To exit the test, press the #5 (<) keypad. The control
will return to the testing mode.