Alliance Laundry Systems PHM1263R Washer User Manual


 
Programming Control
29
F8208801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming Drain Step
1. When “drAn” appears in the display, press the
START (enter) keypad. The current status will be
displayed.
2. Press the #3 ( ) or the #6 ( ) keypad to change
the current status.
on = Drain step is enabled
oFF” = Drain step is disabled
NOTE: Drain must be enabled to activate Extract
step.
3. Press the START (enter) keypad when the
desired status appears in the display. The next
Cycle Segment option, “SPIn”, will appear in the
display.
NOTE: To program “SPIn” (Extract Step),
continue to next Cycle Segment option. To program
other options press the #3 ( ) or the #6 ( ) keypad
and refer to the appropriate section.
How to Exit Programming Feature
Press the #5 (<) keypad until the control returns to
Ready Mode.
Programming Extract Step
1. When “SPIn” appears in the display, press the
START (enter) keypad. The first Extract step
programming option will appear in the display.
2. Press the #3 ( ) or the #6 ( ) keypad to scroll
through the programmable Extract step options.
Refer to Table 9.
NOTE: Extract Step “
SPEn” must be enabled to
scroll through all Extract step options.
3. Press the START (enter) keypad when the
desired option appears in the display. The current
status/value will appear in the display. Refer to
Table 9.
M
4. Press the #3 ( ) or the #6 ( ) keypad to change
the current status/value.
5. Press the START (enter) keypad when the
desired status/value appears in the display.
NOTE: To program “Cnin” (Cycle Time Display),
continue to next Cycle Segment option. To program
other options press the #3 ( ) or the #6 ( ) keypad
and refer to the appropriate section.
How to Exit Programming Feature
Press the #5 (<) keypad until the control returns to
Start Mode.
>
<
>
<
>
<
Extract
Step
Description Status/Value
“SPEn” Extract Step
Enable/
Disable
“on”/“oFF”
“SSEC” Extract
Seconds
0-59
“SnIn” Extract
Minutes
Intermediate Extract:
Minimum
Step Time = 30 seconds
Maximum
Step Time = 3:59 minutes
Final Extract:
Minimum
Step Time = 30 seconds
Maximum
Step Time = 9:59 minutes
“SSPd” Extract Speed
(VFD only)
1 = very low speed (60g)
2 = low speed
(L-speed = 100g;
M-speed = 120g)
3 = medium speed
(L-speed = 100g;
M-speed = 180g)
Table 9
>
<
>
<