Washer-Extractor Operation
Start Up
When power is applied to the washer-extractor, the
control will display its software version as “S XX
(“XX” is the version number) for one second. If the
control was not powered down during a running cycle,
it will enter Start Mode.
Door Locking Mode
The control enters this mode after the START (enter)
keypad is pressed in Start Mode. The control stays in
Door Locking Mode until it confirms the door is
closed and locked.
Stop Mode
The control enters this mode if the user stops the cycle
by pressing the STOP keypad. If control does not
detect water or cylinder rotation it will enter End Of
Cycle mode.
Start Mode
The control enters this mode when machine is ready
for operation. The display will show “CYxx” where
xx” is the cycle number.
After pressing the START keypad, with the door
closed and locked, the cycle will begin. The cycle
cannot be changed once the cycle has started.
End of Cycle Mode
When a cycle is complete, the control will display “00
and will prompt for door unlock by flashing STOP/
UNLOCK LED until the washer door is unlocked and
opened. When this event occurs, the display will revert
back to Start Mode.
Cycle Sequence
Upon the start of a cycle, the control will display the
total cycle time. The appropriate LEDs will light while
the machine passes through different cycle steps. The
user will not be able to change cycles or water
temperature.
Run Mode
The control enters this mode when a cycle is running.
The time remaining appears in the display, the status
LED’s are lit and the loading door is locked.
Signals
There are two options when a signal can be used during
the washer operation. These two options are listed below:
1. End of Cycle Signal
By default, this signal is turned off. If turned on, the
signal sounds for three (3) seconds at the end of a
cycle.
2. Signal On Keypad Depression
By default, this signal is turned on and sounds for
a quarter of a second each time a keypad is pressed.
NOTE: Refer to Programming Control to program
signal options.