Alliance Laundry Systems PHM1263R Washer User Manual


 
Programming Control
33
F8208801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
10. Cold Water Temperature “FC”
This option allows the owner to program the cold
water temperature for models equipped with
temperature sensing capabilities.
How to Program Cold Water Temperature
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the #3 ( ) or the #6 ( ) keypad until
Prog” appears in the display. Press the START
(enter) keypad and “dCYC” will appear in the
display.
3. Press the #3 ( ) or the #6 ( ) keypad to scroll
through the programmable options until “FC
appears in the display.
4. When “FC” appears in the display, press the
START (enter) keypad. A number will appear in
the display. This number corresponds to the
current Cold Water Temperature value.
5. Press the #3 ( ) or the #6 ( ) keypad to increase
or decrease the current Cold Water Temperature
value to the desired Cold Water Temperature
value.
NOTE: Cold Water Temperature is selectable
between 35° and 194° Fahrenheit (2° and 90°
Celsius). Default temperature value is 35°
Fahrenheit (2° Celsius).
NOTE: Refer to option 7 to select Celsius or
Fahrenheit display.
6. Press the START (enter) keypad when the correct
number appears in the display. The next option,
Codn”, will appear in the display.
NOTE: To program “Codn” (Cooldown Enable/
Temperature), refer to option 11. To program other
options, refer to the appropriate section.
How to Exit Programming Feature
Press the #5 (<) keypad until the control returns to
Start Mode.
11. Cooldown Enable/Temperature
“Codn”
This option allows the owner to enable or disable the
Cooldown Water Temperature option. If enabled, the
owner can also set the cooldown water temperature.
How to Program Cooldown Enable/
Temperature
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the #3 ( ) or the #6 ( ) keypad until
Prog” appears in the display. Press the START
(enter) keypad and “dCYC” will appear in the
display.
3. Press the #3 ( ) or the #6 ( ) keypad to scroll
through the programmable options until “Codn
appears in the display.
4. When “Codn” appears in the display, press the
START (enter) keypad. A number or “off” will
appear in the display. The number corresponds to
the current Cooldown Water Temperature value,
and “oFF” appears when cooldown is disabled.
5. Press the #3 ( ) or the #6 ( ) keypad to change
the current status.
NOTE: Cooldown Water Temperature is selectable
between 50° and 160° Fahrenheit (10° and 71°
Celsius). Default is off.
6. Press the START (enter) keypad when the
desired value appears in the display.
NOTE: Refer to option 7 to select Celsius or
Fahrenheit display.
7. Press the START (enter) keypad when the correct
number appears in the display. The next option,
PtEn”, will appear in the display.
NOTE: To program “PtEn” (Production Test Cycle
[on/off]), refer to option 12. To program other
options, refer to the appropriate section.
How to Exit Programming Feature
Press the #5 (<) keypad until the control returns to
Start Mode.
>
<
>
<
>
<
>
<
>
<
>
<