Error Codes
Following is a list of possible error codes for an
electronic control. Errors beginning with “EI” refer to
external device Infra-red communication errors. All
other errors refer to machine errors.
Display Description
Cause/
Corrective Action
EI01 Transmission Failure Communication failure. Re-aim external device and try again.
EI02 Time-out Error Communication failure. Re-aim external device and try again.
EI03 Invalid Command Code Communication successful, but the command was not valid
for this machine type, or the control could not perform the
command in its current mode of operation. Ensure data is for
current machine type and control is in correct mode.
EI04 Expecting Upload Request Communication failure. Re-aim external device and try again.
EI05 Invalid or Out-of-Range Data The value in at least one of the programming options is
invalid or out of range. Recheck the programming option’s
value and try again.
EI09 CRC-16 Error Communication failure. Re-aim external device and try again.
EI0A Framing Error Communication error. Re-aim external device and try again.
EI0C Time-out Exceeded Communication error. Re-aim external device and try again.
EI0E Encryption Error Communication error. Re-aim external device and try again.
If the problem persists, check that the security code is correct.
EI0F Infra-red Disabled Communication failure or infra-red is disabled. Manually
enable infra-red on control or re-aim external device and try
again.
E FL Fill Error Programmed water level not reached within 10 minutes (or
other programmed length of time) in any fill agitate cycle.
End cycle. Power down machine to clear.
E SP SPI Communications Error Front End control cannot communicate with output board.
Power down the machine, power up and try again.