Alliance Laundry Systems PHM1263R Washer User Manual


 
Programming Control
35
F8208801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
14. No Cycle Time Display “nCtd”
This option allows the owner to enable or disable
whether the cycle time will appear in the display.
How to Program in the Cycle Time Display
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the #3 ( ) or the #6 ( ) keypad until
Prog” appears in the display. Press the START
(enter) keypad and “dCyC” will appear in the
display.
3. Press the #3 ( ) or the #6 ( ) keypad to scroll
through the programmable options until “nCtd
appears in the display.
4. When “nCtd” appears in the display, press the
START (enter) keypad. The current No Cycle
Time Display status will appear in the display.
on” = Option Enabled
oFF” = Option Disabled
5. Press the #3 ( ) or the #6 ( ) keypad to change
the current status.
6. Press the START (enter) keypad when the
desired status appears in the display. The next
option, “PCtd” will appear in the display.
NOTE: To program “PCtd” (Programmable Cycle
Time Display), refer to option 15. To program other
options, refer to the appropriate section.
How to Exit Programming Feature
Press the #5 (<) keypad until the control returns to
Start Mode.
15. Programmable Cycle Time
Display “PCtd”
NOTE: This option is available on Software
Version 2 only.
This option allows the owner to display either the
normal remaining cycle time or the programmed time
during a machine cycle.
How to Program the Programmable Cycle
Time Display
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the #3 ( ) or the #6 ( ) keypad until
Prog” appears in the display. Press the START
(enter) keypad and “dCyC” will appear in the
display.
3. Press the #3 ( ) or the #6 ( ) keypad to scroll
through the programmable options until “PCtd
appears in the display.
4. When “PCtd” appears in the display, press the
START (enter) keypad. The current
Programmable Cycle Time Display status will
appear in the display.
0” = Option Disabled
1” = Option Enabled
5. Press the #3 ( ) or the #6 ( ) keypad to change
the current status.
6. Press the START (enter) keypad when the
desired status appears in the display. The next
option, “SdAd”, will appear in the display.
NOTE: To program “SdAd” (Slow Drain
Detection Adjust), refer to option 16. To program
other options, refer to the appropriate section.
How to Exit Programming Feature
Press the #5 (<) keypad until the control returns to
Start Mode.
>
<
>
<
>
<
>
<
>
<
>
<