Alliance Laundry Systems PHM1263R Washer User Manual


 
Programming Control
15
F8208801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Manual Programming Flowchart (1 of 3)
PHM1280R
Figure 3
PHM128
“AUd” - Program when the signal will sound.
“Err-” - Turn on/off certain errors in control.
“E FL” - Fill Error
“E dr” - Drain Error
“E Ub” - Unbalance Error (VFD only)
“E Sd” - Slow Drain Detection
“FILL” - Program fill step options
“LEr-” - Leak Detection
“E oP” - Open Thermistor Error
(temp sensor only)
“E SH” - Shorted Thermistor Error
(temp sensor only)
“LEr1” - Water Leak Detection During
a Machine Cycle
“LEr2” - Water Leak Detection - Day
of Week
“dCYC” - Set the default cycle and
temperature.
“Cy--” - Program aspects for the various
steps in each type of cycle. There are (30)
cycles available for programming.
(continued)
“SEg1” - Program options for each
segment. There are (8) segments
available for programming
“SgEn” - Segment Enabled/Disabled:
“on” = Enabled
“oFF” = Disabled
“tyPE” - Agitation Type:
1 = 18/3/18
2 = 10/20/10
3 = 3/27/3
4 = 4/56/4
“ASPd” - Agitation Speed (VFD only):
“Lo” = Reduced Speed
“rEg” = Normal Speed
“AgIt” - Program the cycles agitation
action and speed
(continued)
““FLEn” - Fill Step Enable/Disable:
“on” = Enabled
“oFF” = Disabled
“FLEU” - Fill Level:
“HI” = High Level
“nEd” = Medium Level
“Lo” = Low Level
“1-30” = Fill Level
“tEnP” - Fill Temperature:
“CoLd” = Cold
“UArn” = Warm
“Hot” = Hot
(35˚F - 194˚F [2˚C - 90˚C])
“E Ht” - Heat Error (heater only)