Alliance Laundry Systems PHM1263R Washer User Manual


 
11
F8208801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming Control
What Can Be Programmed?
This feature allows the owner to program cycle
information and other features by using the keypads.
The control must have the Manual Programming
Mode enabled, which is the factory default. This mode
can only be turned “OFF” and “ON” by using an
external device. Refer to this section when programming
the control.
This section offers a detailed description of all available
programmable options.
Each description includes instructions on when and
why the option might be used and, more importantly,
how to program the option.
For more advanced users, a quick reference list (refer
to Table 1) of the options available through the
programming mode is available. Programming
flowcharts (refer to Figures Figure 2-Figure 6) are
located on the following pages.
NOTE: The letters and numbers in the Option
Display column of the Programmable Options List
are what will be shown in the display when that
option is selected.
Programmable Options Available
Option
Number
Option
Display
Description Default
Value
Value Range
1“dCYC Default Cycle Cy05”* Cy01”-“Cy30”*
2“AUd Audio Signal 29”* 0”-“31”*
3“Err-” Errors ——
a.
E FL Fill Errors on”“on”/“oFF
b.
E dr Drain Error on”“on”/“oFF
c.
E Ub Unbalance Error Display on”“on”/“oFF
d.
E oP Open Thermister Error Display on”“on”/“oFF
e.
E SH Shorted Thermistor Error Display on”“on”/“oFF
f.
E Ht Heat Error Display (Heater only) on”“on”/“oFF
g.
LEr- Water Leak Detection Error
1.
LEr1 1. Water Leak Detection During a Machine Cycle
(On/Off)
oFF”“on”/“oFF
2.
LEr2 2. Water Leak Detection Day of Week Enable 127”* 0”-“127”*
3.
LEr3”*** 3. Number of Cycles Between Water Leak
Detection During a Machine Cycle
0”“0”-“127
h.
ESd Slow Drain Detection oFF”“on”/“oFF
4“Cy--” Cycle Programming Refer to Operation Manual for default cycle
information
a.
AgIt Cycle Agitate ——
1.
tyPE Agitate Type ** 1”-“4”*
2.
ASPd Agitate Speed (VFD only) ** Lo”/“rEg”*
b.
Segx
(1-8)
Cycle Segment Programming ——
1.
SgEn Segment Enable/Disable ** on”/“oFF
Table 1 (continued)