Alliance Laundry Systems PHM1263R Washer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming Control
F8208801
22
3. Error Code Programming “Err-”
This option allows the owner to turn on or turn off
certain errors in the control.
How to Program Error Code Programming
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the #3 ( ) or the #6 ( ) keypad until
Prog” appears in the display. Press the START
(enter) keypad and “dCYC” will appear in the
display.
3. Press the #3 ( ) or the #6 ( ) keypad to scroll
through the programmable options until “Err-
appears in the display.
4. When “Err-” appears in the display, press the
START (enter) keypad. Refer to Table 3 for a list
of programmable error code parameters.
5. Press the #3 ( ) or the #6 ( ) keypad to select
error code.
6. Press the START (enter) keypad when the correct
code appears in the display. The current status
will appear in the display.
on = Error Code Enabled
oFF” = Error Code Disabled
7. Press the #3 ( ) or the #6 ( ) keypad to change
the status.
8. Press the START (enter) keypad when the correct
status appears in the display. The next Error Code
Programming option will appear in the display.
NOTE: To program “Cy--” (Cycle Programming),
press the #5 (<) keypad, then the #3 ( ) keypad and
refer to option 4. To program other options, refer to
the appropriate section.
How to Exit Programming Feature
9. Press the #5 (<) keypad until the control returns
to Start Mode.
>
<
>
<
>
<
>
<
>
“E FL” Fill Error
“E dr” Drain Error
“E Ub” Unbalance Error Display (VFD only)
“E oP” Open Thermistor Error Display
“E SH” Shorted Thermistor Error Display
“E Ht” Heat Error Display (Heater only)
“LEr-” Leak Detection Error
If water leak detection during a machine
cycle is enabled, then, on the enabled day(s)
of the week, the control will check for water
leaks during running machine cycles. If a
leak is detected, the control will display the
ELd” error for one minute after the cycle
is completed. It will also light the right-most
decimal point on the display. To turn off the
right-most decimal point on the display,
press the START keypad 3 times (within 5
seconds) anytime after the first fill. The
water leak detector diagnostic test can be
used to verify the leak.
“LEr1”
Water Leak Detection During
a Machine Cycle - Determines
if water level drops below
target level.
“LEr2”
Water Leak Detection During
Machine Cycle Day of Week
Enable (Refer to Figure 3 for
Day(s) of the Week Enabled
Values)
“LEr3”
Number of Cycles Between
Water Leak Detection During
a Machine Cycle (Option not
available on Software
Version 1.)
“ESd” Slow Drain Detection Determines if
machine is draining slower than normal.
If Slow Drain Detection is enabled, the
control will check for slow drain operation
during running machine cycles. If a slow
drain is detected, the control will display the
ESd” error for one minute after the cycle is
completed. It will also light the right-most
decimal point on the display. For machines
equipped with Software Version 2, to turn
off the right-most decimal point on the
display, press the START keypad 3 times
(within 5 seconds) anytime after the first fill.
Table 3