Testing Machine and Electronic Control Functions
49
F8208801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Production Test Cycle Quick Reference Chart
Display Test Cycle Step Comments
“S xx” FEC Control Software
Versi on
xx is the software version number.
“o xx” Output Board Software
Versi on
xx is the software version number.
“Ct 3” Control Type xx is the control type.
“oPL” Control Type OPL.
“USA” Control Type Domestic
“drAn” or “PUnP” Drain Type Drain or Pump.
“tEnP” Temp Sensor Step skipped if not Temperature Sensor-equipped.
“HEAt” Heater Step skipped if not heater-equipped.
“rot” Rotation Sensor Step skipped if not Rotation Sensor-equipped.
“L dC” or “L AC” Door Lock Type “L dC” if 24 VDC lock or “L AC” if 240 VAC unlock solenoid.
“droP” or “drCL” Door Status Door open or closed.
“drUL” or “drLo” Door Lock Status Door will lock.
8.8.8.8.” + all LEDs Display Test All display elements are lit.
PAxx” where xx = 1
through 12
Keypad Test step Advance after all keypads are pressed.
A xx Access Panel Switch Test xx is either “CL” for closed or “oP” for open.
“Cxxx” or “Pxxx” Machine Type/Size
“HFIL” Hot Fill to Low Level All water turned off when Low Level reached.
“CFIL” Cold Fill to Low Level All water turned off when Low Level reached.
“bFIL” Warm Fill to Low Level All water turned off when Low Level reached.
“bFIH” Warm Fill to High Level All water turned off when High Level reached.
“S1” for supply or
“C2Co” for compartment
Supply #1 or Compartment
#2 Cold Fill
“S2” for supply or
“C2Ho” for compartment
Supply #2 or Compartment
#2 Hot Fill
“S3” for supply or
“C3Co” for compartment
Supply #3 or Compartment
#3 Cold Fill
“S4” for supply or
“C4Ho” for compartment
Supply #4 or Compartment
#4 Hot Fill
“oFLo” Warm Fill to Overflow
“xxxF” degrees F or
“xxxC” degrees C
depending on the
Fahrenheit/Celsius
programming parameter
Heat water to 110°F or
display temperature
xxx is degree temperature. This step skipped if not temp-sensor-
equipped. Heater turned off when temperature reached.
Table 15 (continued)