© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming Control
F8208801
12
Table 1 (continued)
Option
Number
Option
Display
Description Default
Value
Value Range
c.
“FILL” Fill Step ——
1.
“FLEn” Fill Step Enable/Disable ** “on”/“oFF”
2.
“FLEU” Fill Level ** “HI”/“nEd”/“Lo” or 1-30
3.
“tEnP” Fill Temperature ** “CoLd”/“Uarn”/“Hot”o r
35°F-194°F/2°C-90°C
d.
“SUPL” Supply Step ——
1.
“SUEn” Supply Step Enable/Disable ** “on”/“oFF”
2.
“dISP” Dispenser Options ** Display will show “Sx”
3.
“S1” Supply #1 ** “on”/“oFF”
4.
“S2” Supply #2 ** “on”/“oFF”
5.
“S3” Supply #3 ** “on”/“oFF”
6.
“S4” Supply #4 ** “on”/“oFF”
7.
“SdUr” Supply Duration ** Press START keypad to access
options
8.
“SEC” Seconds ** 0-59
9.
“nIn” Minutes ** 0-9
e.
“AgSt” Agitate Step
——
1.
“AgEn” Agitate Step Enable/Disable ** “on”/“oFF”
2.
“AdUr” A g i t a t e D u r a t i o n ( in min u t e s ) * * 1 - 3 0 f o r a g i t a t e types 1 o r 2 ;
1-180 for agitate types 3 or 4
3.
“HEAt” Heat in Agitate (if heater is present) “oFF” (Rinse)
“2” (Wash)
“oFF”/“1”/“2”**
f.
“drAn” Drain Step —“on”/“oFF”
g.
“SPIn” Spin Stop ——
1.
“SPEn” Extract Step Enable/Disable ** “on”/“oFF”
2.
“SSEC” Extract Seconds ** 0-59
3.
“SnIn” Extract Minutes ** Intermediate Extract:
Min. Step Time = 30 seconds,
Max. Step Time = 3:59 minutes
Final Extract:
Min. Step Time = 30 seconds,
Max. Step Time = 9:59 minutes
4.
“SSPd” Extract Speed (VFD only) ** “1”-“3”*
h.
“Cnin”*** Cycle Time in Minutes (If PCtd is enabled) 00-255 minutes
5“bALr” Number of Balance Retries (VFD only) 31-7
6“IrA” IR Access (On/Off) “on”“on”/“oFF”
7“t FC” Fahrenheit/Celsius “FAHr”
(Fahrenheit)
“FAHr” (Fahrenheit)/“CEL
”
(Celsius)
8“FH” Hot Water Temperature 140°F (60°C) 35°F-194°F/2°C-90°C
9“FHC” Warm Water Temperature 100°F (38°C) 35°F-194°F/2°C-90°C
10 “FC” Cold Water Temperature 35°F (2°C) 35°F-194°F/2°C-90°C
Table 1 (continued)