Table 7. Operator Intervention Messages and Parameters (OPINT TRAP Type) (continued)
OPINT #
Parameter
[A]
Parameter
[B]
Parameter
[C]
Actual Library Manager OPINT Trap
Message
36 — — — A mislabeled cleaner cartridge has been
ejected to the convenience output station.
37 — — — A mislabeled cleaner cartridge has been
ejected to the high-capacity output station.
38 Rack Cell — — A cartridge or cartridge label located at cell
[A] is upside_down.
39 Rack Cell — — A duplicate Volser has been found at cell
[A].
40 Rack Cell — — The cartridge label located at cell [A] is
unreadable.
41 Rack Cell — — The cartridge label located at cell [A] is
invalid.
42 — — — The system has failed. A service call is
required.
43 — — — *The accessor or gripper configuration has
changed. The library must be re-taught.
44 — — — *The top two I/O station cells are
inaccessible. Move cartridges to cell 3.
45 Volser Rack Cell — Volser ([A]) cannot be removed from cell:
[B]
46 Volser Rack Cell — Volser ([A]) cannot be removed from
high-capacity station cell: [B]
47 Device — — Device [A] has failed. A service call is
required.
48 Device — — A cartridge containing invalid media has
been left in device [A] feed slot. Remove
the cartridge.
49 Volser — — An invalid media volser ([A]) has been
ejected to the convenience I/O station.
50 Volser — — An invalid media volser ([A]) has been
ejected to the high-capacity output station.
51 — — — *The library is out of HPCT cleaner
cartridges.
52 Volser — — A volser ([A]) with an unknown media type
has been ejected to the convenience I/O
station.
53 Volser Rack Cell — A volser (A) with an unknown media type
has been ejected to high-capacity output
facility cell: [B]
54 Volser — — Volser (A) cannot be removed from
convenience I/O station.
55 VTS Number — — Free storage threshold has been crossed for
VTS [A].
56 Volser — — A volser (A) with an unknown media type
has been left in to the convenience input
station.
218 Magstar 3494 Tape Library Operator Guide