Table 7. Operator Intervention Messages and Parameters (OPINT TRAP Type) (continued)
OPINT #
Parameter
[A]
Parameter
[B]
Parameter
[C]
Actual Library Manager OPINT Trap
Message
9 Volser — — An unexpected volser ([A]) was found and
ejected to the convenience I/O station.
10 — — — *The high-capacity output rack is full.
11 Volser Rack Cell — A duplicate volser ([A]) was left in
high-capacity input rack cell [B]
12 Rack Cell — — An unreadable volser was left in
high-capacity input rack cell [A]
13 Volser Rack Cell — An invalid volser ([A]) was left in
high-capacity input rack cell B
14 Volser — — An invalid volser ([A]) was left in the
convenience I/O station
15 Volser Rack Cell — A duplicate volser ([A]) was ejected to
high-capacity output rack cell [B]
16 Volser Rack Cell — An unexpected volser ([A]) was ejected to
high-capacity output rack cell [B]
17 Device — — Load / unload failure on device [A].
18 Volser — — An unexpected volser ([A]) was left in the
convenience I/O station.
19 Volser Rack Cell — An unexpected volser ([A]) was left in
high-capacity output rack cell [B]
20 — — — *The convenience I/O station door is open.
21 — — — *The convenience I/O station door is open.
22 Volser — — Volser ([A]) could not be put away. It was
ejected to the convenience I/O station.
23 Volser Rack Cell — Volser ([A]) could not be put away. It was
ejected to the high-capacity output rack cell
[B].
24 — — — The convenience I/O station should be
empty but is not. Visually check the station.
25 Gripper Accessor — A cartridge could not be released from
gripper [A] accessor [B].
26 Volser — — A cartridge has been dropped. ([A])
27 — — — Environmental alert - Smoke has been
detected in the enclosure.
28 — — — An emergency stop has occurred.
29 Volser — — Damaged volser ([A]) ejected to the
convenience I/O station.
30 Volser Rack Cell — Damaged volser ([A]) ejected to
high-capacity output facility cell: [B]
31 Device — — Device [A] is not ready.
34 Device — — A mislabeled cleaner cartridge has been left
in device [A] feed slot. Remove the
cartridge.
35 Device — — A recoverable error occurred on device [A].
A service call may be needed if the error
persists.
Chapter 6. Advanced Operating Procedures 217