Emerson 3-9000-744 Washer User Manual


 
24 Steps to remove a transducer assembly from a meter while the meter is under line pressure
Section 4: Removing a transducer assembly Operation Manual
September 2013 3-9000-744 Rev F
g. Remove the transducer assembly (J) (Figure 4-4, E) from the transducer stalk
assembly (D) (Figure 4-4, C) or, on some meters, the transducer holder (K)
(Figure 4-4, A) by unscrewing the three set screws (W) (Figure 4-4, D) on the
transducer stalk assembly (D) or, transducer holder (K) (Figure 4-4, B). Clean or
replace the transducer assembly (J) as needed.
Figure 4-4 Transducer holder, stalk and transducer assembly
h. Review the Part Replacement notes in Section 2.2 for instructions on
replacement of transducer assemblies (J) and other mounting parts.
A.
B.
E.
A. Transducer holder
B. Transducer holder set screws
C. Transducer stalk assembly
C.
D. Transducer stalk assembly set screws
D.
E. Transducer assembly