Operation Manual Section 1: Introduction
3-9000-744 Rev F September 2013
Overview 3
Daniel Ultrasonic meters with M-mount (150 ANSI to 600 ANSI) or P-mount
(900 ANSI to 1500 ANSI) T- slot transducer holders are not designed for the Split Clamp
Extractor Tool and this manual does not apply to these mount styles. M-mount and P-mount
bodies are threaded to accept extractor tool coupling and will not accept split clamp extractor
tool (see Figure 1-3). Refer to the Daniel Ultrasonic Extractor Tool Operation Manual,
Daniel P/N 3-9000-729 for threaded body types.
Figure 1-3 M-mount transducer identification
Important:
The ultrasonic extractor tool requires a valve with an NPT female threaded port as a pressure
point for the line pressure. This valve must be installed within six inches of the ultrasonic meter
pressure tap hole provided on the ultrasonic meter housing.
For ANSI #300 and #600 meters, use a valve with a ¼”or ½” NPT female threaded port.
The ¼” reducer provided in the tool kit must be used with the ½” NPT female threaded port.
For ANSI #900 and #1500 meters, use a valve with a “or ½” NPT female threaded port. The
“reducer provided in the tool kit must be used with the ½”NPT female threaded port.
A.
A. Mount identification (serial number, length, purchase order number and style)
B. Threaded mount
B.