B-10 Parameters, Settings, and Defaults
2325 Reference Guide Revision B 2325A137REFGD
Defaults
Code Parameters I.D. # Type Acceptable Input D0 D1 D2
Good-read beep
duration
BA Value 00 = 0.07 sec.
01 = 0.13 sec.
02 = 0.18 sec.
03 = 0.36 sec.
00 00 00
Beeper volume BC Value 00 = Off
01 - 09
(01 = Lowest;
07 = Highest;
08 = Higher;
09 = Lower)
07 07 07
Error beep tone BD Value 00 = 2400 Hz
01 = 2580 Hz
02 = 2770 Hz
03 = 3000 Hz
04 = 3270 Hz
05 = 3600 Hz
06 = 4000 Hz
07 = 4520 Hz
01 01 01
Long-range trigger
mode
(long-range scanner
models only)
D4 On/Off On = Release Scan
Off = Spot Timeout
Off Off Off
Spot beam timeout
(long-range scanner
models only)
D5 Value 00 = 0.25 sec.
01 = 0.50 sec.
02 = 1.00 sec.
03 = 1.50 sec.
04 = 2.00 sec.
01 01 01
Release scan timeout
(long-range scanner
models only)
D6 Value 01 - 30 (seconds) 02 02 02
Spotting Beam
Enable
D7 On/Off On or Off On On On
Keypress sound DD Value 00 = Off
01 = Click
02 = Beep
01 01 01
Enable CTL-ALT-
DEL reboot
E0 On/Off On or Off Off Off On