A SERVICE OF

logo

Parameters, Settings, and Defaults B-5
2325A137REFGD Revision B 2325 Reference Guide
Codabar/Ames
Enter 1 for On and 0 for Off.
Defaults
Code Parameters I.D. # Type Acceptable Input D0 D1 D2
Enable 20 On/Off On or Off Off On On
Minimum length 21 Value 01 - 50 01 01 04
Maximum length 22 Value 01 - 50 01 50 20
Send start/stop 23 On/Off On or Off Off On Off
Codabar-to-CLSI
conversion
24 On/Off On or Off Off Off Off
Wide intercharacter
gaps allowed
25 On/Off On or Off Off Off On
MSI
Enter 1 for On and 0 for Off.
Defaults
Code Parameters I.D. # Type Acceptable Input D0 D1 D2
Enable 26 On/Off On or Off Off On Off
Minimum length 27 Value 01 - 14 01 01 04
Maximum length 28 Value 01 - 14 01 14 10
Require 2 check digits 29 On/Off On or Off Off Off Off
2nd check digit Mod
11
2A On/Off On or Off Off Off Off
Send check digit(s) 2B On/Off On or Off Off On Off