K400 Issue No. 1 33
RTD Measurements
The DBC-TC series can measure the electrical output of RTD, displaying the value
directly in the selected temperature unit.
From the Menu Selection Screen, using the select RTD and press ent.
After selection of the generation mode, a new display shows the RTD types that can
be measured.
Using the keys to select the required RTD type and press ent. After this
operation, a new display sets the connection configuration (3 or 4 wires) of the
probe under test.
Using the keys, select the required connection configuration and press ent.
MEASURE
INTERNAL
SEL RTD
NONE
T/C
mA
RTD
REF T.
TYPE
Pt-100
Pt-200
Pt-500
Pt-1000
Ni-100
RTD
3 WIRES
4 WIRES