3.3.5 Pulse Motor (Main)
(1) Remove the upper cover (see 3.3.1).
(2) Remove the connector 3 from (CN2) 2 of the Main Control PCB 1.
(3) Remove two screws 4 and remove the pulse motor (main) 6 from the motor bracket 5.
View A
6
4
4
5
2
1
CN2
3
CN2
OKIPAGE 6ex OKIPAGE 6e