A SERVICE OF

logo

6 - 13
Category
Controller errors
ERROR nn
Error Remedy
LCD status message Trouble or status Remedy
Check the optional RAM board
for proper connection.
Check the mounting position of
short plugs and additional RAM
chips (see 7.4).
Replace the option RAM board.
60 An error was detected by
optional RAM check.
Check the fan motor for proper
connection and for any presence
of foreign matter in the fan (see
6.5.2-5).
Replace the fan or the Main
Control PCB.
70 A fault occurred in the Fan
motor.
See 6.5.2-4.71 A fault occurred in the fuser
(timeout error etc.).
See 6.5.2-4.72 A fault occurred in the fuser
(thermistor open error).
See 6.5.2-4.73 A fault occurred in the fuser
(thermistor short error).
Replace the power supply board
or the Main Control PCB.
74 Power supply board SSIO
I/F error
Check the operator panel for
proper connection.
Replace the flexible cable,
operator panel or Main Control
PCB.
80 I/F timeout occurred between
the Main Control PCB and
the operator panel.
Code
(nn)
Table 6-2 (Cont'd)