Controller errors
ERROR nn
Error Remedy
LCD status message Trouble or status Remedy
Check the optional tray for proper
connection.
81 I/F timeout occurred between
the Main Control PCB and
the optional tray (2nd tray,
envelope feeder, etc.).
Turn the power off, then back
on to recover from the error.
Replace the Main Control PCB.
90 A watchdog timer timeout
occurred.
Check valid CPU list.91 Invalid CPU was used.
Close the cover to release the
error display.
If the display does not change
after this procedure, replace the
power supply board.
The upper cover was opened.
Check the paper in the cassette.
Open and then close the cover.
When the cover is closed,
recovery printing is carried out
and the error display is released.
If this error occurs frequently,
see 6.5.2 2-1.
A jam occurred during paper
hopping from the tray being
displayed .
tray: TRAY 1, TRAY 2, FEEDER
Cover open
Jam errors
COVER
OPEN
tray
INPUTJAM
Code
(nn)
Table 6-2 (Cont'd)