American Dryer Corp. AD-200 PHASE 7 Clothes Dryer User Manual


 
98
I/O Board Input Description (Red L.E.D.)
1. FDRC (RED L.E.D.) This L.E.D. will indicate the status of the Front Doors. If the doors are closed,
then the L.E.D. is ON.
2. FDRO (RED L.E.D.) This L.E.D. will indicate the status of the Front Doors. If the doors are open,
then the L.E.D. is ON.
3. TBOL (RED L.E.D.) This L.E.D. will indicate the status of the Tumbler (Basket) Overload Contact.
If the contact is closed, then the L.E.D. is ON. If it faults open, then the L.E.D.
is OFF.
4. FNOL (RED L.E.D.) This L.E.D. will indicate the status of the Fan Overload Contact. If the contact
is closed, then the L.E.D. is ON. If it faults open, then the L.E.D. is OFF.
5. RDWN (RED L.E.D.) This L.E.D. will indicate the status of the Rear Tilt. If the rear of the dryer is
down, then the L.E.D. is ON.
6. FDWN (RED L.E.D.) This L.E.D. will indicate the status of the Front Tilt. If the front of the dryer is
down, then the L.E.D. is ON.
7. RDRC (RED L.E.D.) This L.E.D. will indicate the status of the Rear Doors. If the doors are closed,
then the L.E.D. is ON.
8. RDRO (RED L.E.D.) This L.E.D. will indicate the status of the Rear Doors. If the doors are open,
then the L.E.D. is ON.
9. FAN (RED L.E.D.) This L.E.D. will indicate the status of the Blower Fan. If the fan is on, then the
L.E.D. is ON.
10. RBHL (RED L.E.D.) This L.E.D. will indicate the status of the Rear Burner High Limit Disk. If the
disk is closed (Temp below 225º F [107º C]), then the L.E.D. is ON.
11. R_SS (RED L.E.D.) This L.E.D. will indicate the status of the Rear Sail Switch. If the switch is
closed, then the L.E.D. is ON.
12. FBHL (RED L.E.D.) This L.E.D. will indicate the status of the Front Burner High Limit Disk. If the
disk is closed (Temperature below 225º F [107º C]), then the L.E.D. is ON.
13. F_SS (RED L.E.D.) This L.E.D. will indicate the status of the Front Sail Switch. If the switch is
closed, then the L.E.D. is ON.
14. EXHL (RED L.E.D.) This L.E.D. will indicate the status of the Exhaust High Limit Disk. If the disk
is closed (Temperature below 225º F [107º C]), then the L.E.D. is ON.
15. DRY (RED L.E.D.) This L.E.D. will indicate the status of the PLC. If the mechanical functions of
the dryer have been set to the DRY position, the PLC will send a signal to the
Phase 7 board. This signal will indicate that
ALL the doors are closed and the
dryer is level. When these conditions are met, then the L.E.D. is ON.
16. LINT (RED L.E.D.) This L.E.D. will indicate the status of the Lint Drawer. If the drawer is closed,
then the L.E.D. is ON.