American Dryer Corp. AD-200 PHASE 7 Clothes Dryer User Manual


 
104
f. V-belts are too tight.
g. Dryer has an oversized load.
h. Voltage to the dryer is incorrect...check dryer data label for specified voltage.
2. Failed overload protector...
a. Incorrect overload setting.
E. Impellor (fan) motor is not operating (does not start)...
* Microprocessor controller (computer) I/O (input/output) board FAN relay output indicator is
on.
1. Blown blower (impellor and fan) motor overloads.
2. Failed blower (impellor and fan) motor contactor (relay).
3. Failed blower (fan and impellor) motor.
4. No 24 VAC present at fan motor contactor coil.
* Microprocessor controller (computer) I/O (input/output) board FAN relay output indicator is
off.
1. Failed microprocessor controller (computer) I/O (input/output) board.
F. Blower (fan and impellor) motor operates okay for a few minutes and then either repeatedly or
occasionally trips the overload protector...
NOTE: When the overload protector trips, the microprocessor controller (computer) I/O (input/
output) board red L.E.D. (light emitting diode) FNOL will be off and the display will read
Fan Overload Fault.
1. Motor is overheating...
a. Motor air vents clogged with lint.
b. Low voltage to motor.
c. Failed motor.
d. Tumbler (Basket) is binding...check for an obstruction.
e. Failed gear reducer or tumbler (basket) bearing.
f. V-belts are too tight.
g. Motor is running at incorrect voltage.