American Dryer Corp. AD-200 PHASE 7 Clothes Dryer User Manual


 
41
12. Open ALL gas shut-off valves (closed in Step #2).
13. Reestablish electrical power to the dryer.
a. Test ALL connections for leaks.
IMPORTANT: Test ALL connections for leaks by brushing on a soapy water solution (liquid
detergent works well).
WARNING: NEVER TEST FOR LEAKS WITH A FLAME!!!
14. Operate the dryer through one (1) complete cycle to insure proper operation.
D. STEAM COIL SYSTEM OPERATION
General Overview
The ADS-200 steam coil is constantly charged thereby eliminating repeated expansion and contraction and also
provide instant heating to start the drying process. The steam damper, located on top of the steam coil, is the only
temperature controlling device in this system. When the steam damper is open, ambient air is drawn through the
coil providing heat to the dryer. When the steam damper is closed, ambient air is drawn directly into the tumbler
(basket), bypassing the coil, allowing a rapid cool down.
NOTE: With the dryer off or no air supply to the damper piston, the damper is in the Cool Down
mode...the coil is constantly charged.